CONFIG Settings
Basic Functions
2
CF15 Voltage setting limit
Set whether to limit the set output voltage so that its value does not exceed the set overvolt-
age protection (approximately 95 % of the OVP trip point) and is not lower than the set under-
voltage limit. When the voltage setting limit is set to “oFF,” if you set the voltage setting limit to
“on” when the set OVP is lower than the set voltage, the voltage value will be maintained, and
the set OVP will be changed to 105 % of the voltage value. In addition, the set UVL will be
changed to match the voltage value. The parameter will also be changed if the output is on.
This is set to “on” when the panel settings are reset (CF00) and when a preset memory entry
is recalled.
You can only specify this parameter when the PWX series is being used as a master unit
.
CF16 Panel display brightness setting
Adjusts the panel display brightness. The larger the number, the brighter the display.
Even if you specify the same number, the brightness may be different between individual
products.
The brightness is not proportional to the setting.
CF17 Communication monitor timer setting
Sets the interval for monitoring SCPI command communication.
The communication monitoring function operates regardless of whether the product is in
remote or local (panel control) mode.
When using local mode (panel control), be sure to specify oFF.
CF18
I
nternal resistance setting (factory option)
Sets the internal resistance (Rint). The internal resistance that you can specify varies
depending on the model. For the internal resistance range, see
You can display and set this parameter only when the variable internal resistance feature
(factory option) is installed.
See
Value
Parameter description
oFF
The setting is not limited.
on
The setting is limited (factory default setting).
Memo
When multiple units are
used side-by-side, if the
brightness of the panel
display is different
between units, you can
adjust it.
Value
Parameter description
1 to 7
Screen brightness (factory default setting: 7).
See
Value
Parameter description
oFF
Communication monitor timer is set to off (factory default setting).
1 to 3000 1 s, 3 s, 10 s, 30 s, 100 s, 300 s, 1000 s, 3000 s
See
Value
Parameter description
oFF
Variable internal resistance feature is not used (factory default setting).
Rint (min) to Rint (max) Rint (min)
Ω
to Rint (max)
Ω
Содержание PWX1500H
Страница 10: ...10 PWX This page is intentionally blank...
Страница 26: ...26 PWX This page is intentionally blank...
Страница 88: ...88 PWX This page is intentionally blank...
Страница 89: ...Maintenance This chapter explains how to perform cali bration DELETE...
Страница 92: ...92 PWX This page is intentionally blank...
Страница 93: ...Specifications This chapter contains the specifications and gives the dimensions of the PWX series...
Страница 120: ...120 PWX This page is intentionally blank...
Страница 121: ...Appendix A Options B Troubleshooting...
Страница 128: ...128 PWX This page is intentionally blank...