PWX
47
CONFIG Settings
Basic Functions
2
CF06 CV control using an Vext or Rext
Selects whether constant voltage will be controlled by an external voltage (Vext) or an exter-
nal resistance (Rext) (the J1 connector).
This is set to “oFF” when the panel settings are reset (CF00) and when a preset memory
entry is recalled.
You can only specify this parameter when the PWX series is being used as a master unit
.
CF07 CV/CC control range parameter
Selects the range that is used when controlling constant current and constant voltage with an
external voltage or an external resistance (the J1 connector).
You can only specify this parameter when the PWX series is being used as a master unit
.
CF08 Range during voltage and current monitoring
Selects the range during voltage and current monitoring.
CF09 External control parameter for turning output on and off
Selects whether an external contact (the J1 connector) will be used to turn output on and off.
This is set to “oFF” when the panel settings are reset (CF00) and when a preset memory
entry is recalled.
You can only specify this parameter when the PWX series is being used as a master unit
.
CF10 External control logic parameter for turning output on and off
Sets the logic that is used when an external contact (the J1 connector) is being used to turn
output on and off.
You can only specify this parameter when the PWX series is being used as a master unit
.
See
Value
Parameter description
oFF
Control will not be performed (factory default setting).
on
Control will be performed.
See
Value
Parameter description
Lo
0 V to 5 V (factory default setting)
Hi
0 V to 10 V
See
Value
Parameter description
Lo
0 V to 5 V (factory default setting)
Hi
0 V to 10 V
See
Value
Parameter description
oFF
External control is not performed (factory default setting).
on
External control is performed.
See
Value
Parameter description
Lo
Output is turned on when a LOW signal (0 V to 0.5 V) or short-circuit is received
(factory default setting).
Hi
Output is turned on when a HIGH signal(4.5 V to 5 V) or open-circuit is received.
Содержание PWX1500H
Страница 10: ...10 PWX This page is intentionally blank...
Страница 26: ...26 PWX This page is intentionally blank...
Страница 88: ...88 PWX This page is intentionally blank...
Страница 89: ...Maintenance This chapter explains how to perform cali bration DELETE...
Страница 92: ...92 PWX This page is intentionally blank...
Страница 93: ...Specifications This chapter contains the specifications and gives the dimensions of the PWX series...
Страница 120: ...120 PWX This page is intentionally blank...
Страница 121: ...Appendix A Options B Troubleshooting...
Страница 128: ...128 PWX This page is intentionally blank...