PFX2532
45
2
C
o
nnec
ting and C
o
nfiguring De
vic
e
s
Configuring the Devices
Configuration procedure of devices
1
Set the channel numbers and vibration sensor using the S1 switch of the
PFX2532.
2
Configure the DC power supply.
Set protection functions, CONFIG settings, and panel lock.
3
Configure the electronic load.
Configure the protection function, slew rate, external analog control, panel lock, and if
necessary, the number of units in parallel operation.
Configuring the PFX2532
You can change the following settings using the S1 switch on the rear panel. If you change a
setting, turn the PFX2532 off and then back on.
•
Channel numbers
•
vibration sensor
See
See
See
Signal name
Logic
Notes
Factory
default
TERMN OFF
1
1
TP-BUS connector is not used on the PFX2532.
Not used
Always set to
zero
0
NC
Not used
Always set to
zero
0
1
Set channel numbers
(1 to 7).
0 is not allowed.
1
2
0
4
0
8
0
RESV
Not used
Always set to
zero
0
SH DET
0: Vibration sensor off
1: Vibration sensor on
0
Factory default switch position
Example of channel number 1
S1
SH DET
RESV
8421
NC
TERMN
OFF
1
0
Содержание PFX2532
Страница 12: ...12 PFX2532 This page is intentionally blank ...
Страница 25: ...Connecting and Configuring Devices This chapter describes how to connect and configure the devices ...
Страница 62: ...62 PFX2532 This page is intentionally blank ...
Страница 71: ...Specifications This chapter provides the PFX2532 s specifications and outline drawing ...
Страница 96: ...96 PFX2532 This page is intentionally blank ...
Страница 141: ......