120
PFX2532
Mounting to the rack
You can mount SL01-PFX to a rack. To rack mount the SL01-PFX, you need a rack mounting option.
For information about options, contact your Kikusui agent or distributor.
Rack mount option
Remove the handle and rubber feet before you mount the SL01-PFX to a rack.
For information on rack mounting, see the KRA3 or KRA150 operation manual.
To support the main unit, attach an angle support to it that is appropriate for the rack.
■
Removing the handle and feet
We recommend that you keep all pieces that you have removed from the SL01-PFX. You will need
these pieces if you remove the SL01-PFX from the rack.
If you remove the SL01-PFX from the rack, re-attach the original rubber feet.
1
Pull up the handle cover (two
locations).
2
Unfasten the two M4 flat
countersunk head screws, and
remove the entire handle.
3
Loosen the screws to remove the
rubber feet (in four locations).
Name
Model
Note
Rack mount frame
KRA3
Inch rack EIA Standard
KRA150
Milli rack JIS Standard
KRA150
(
460
)
480
482 (18.98)
( 460 (18.1
1) )
149
24.5
100
132.5 (5.22)
57 (2.24)
260 (10.24)
260
37.75
(1.49)
KRA3
Unit: mm
Unit: mm (inch)
To reinstall the handle that has been removed, use screw locking agent (e.g., 1401B by ThreeBond
International, Inc.) to prevent screws from loosening.
Attachment screws
(4 locations)
4-M3 screw
Maximum depth:
8 mm (0.31 inch)
Collar (4 locations)
Rubber feet
(4 locations)
Brackets
Handle
Cover
M4 flat screws
(M4x0.7x8)
Содержание PFX2532
Страница 12: ...12 PFX2532 This page is intentionally blank ...
Страница 25: ...Connecting and Configuring Devices This chapter describes how to connect and configure the devices ...
Страница 62: ...62 PFX2532 This page is intentionally blank ...
Страница 71: ...Specifications This chapter provides the PFX2532 s specifications and outline drawing ...
Страница 96: ...96 PFX2532 This page is intentionally blank ...
Страница 141: ......