Check that all accessories are included and that the main unit and
accessories have not been damaged during transportation.
If the main unit or any of the accessories are damaged or missing,
contact your Kikusui agent or distributor.
We recommend that you save all packing materials, in case the
PFX2532 needs to be transported at a later date.
To configure a system, the following cables are necessary in
addition to the included cables.
These cables are available as options (sold separately).
• DC power supply connection cable (+•–): 80 mm
2
• Electronic load connection cable (+•–): 80 mm
2
• Booster connection cable (+•–): 80 mm
2
• DUT cable (+•–) (for connecting the DUT): 80 mm
2
• Sensing cable (voltage / temperature sensing cable)
• Booster connection flat cable: 20 core
• I/F cable for PWR-01 Regulated DC power supply
• I/F cable for PLZ-5W Electronic load
• Parallel cable for electronic loads
Make the cables as short as possible by considering the loss in the
cables (
) according to your system configuration.
If cables are to be connected in a system configuration shown in
“Connecting the devices” on page 31, you can use the optional
cable set.
Use it as a guide in selecting the cables.
For information about options, contact your Kikusui agent or
distributor.
Cable set (
•
I/F cable for PWR-01 Regulated DC power supply
(
)
Checking the Package Contents
Power cord (1 pc.) without plug
(not CE compliant) [85-10-0630]
I/O terminal cover set
Terminal covers (3 pcs.)
Cable ties (6 pcs.)
[Q1-500-085]
[P4-200-001]
x 3
x 6
x 6
x 4
[Q1-500-096]
[Q1-900-020]
[M1-100-012]
[M5-101-007]
[M4-100-007]
Because the power cord
does not comply with CE, it
may not be included
depending on the shipment
destination.
Because the power cord
does not comply with CE, it
may not be included
depending on the shipment
destination.
I/O terminal M8 screw set
(6 sets)
Thermistor (1 pc.)
[38-00-0160]
26-core flat cable (1 pc.)
(I/F cable for PWR1600L
Regulated DC power supplies)
[83-22-6050]
20-core flat cable (1 pc.)
(I/F cable for PLZ-4W
electronic loads)
[91-80-6136]
Sensing Connector (1 pc.)
[84-61-7705]
Lock lever (2 pcs.)
[83-06-5060]
Sensing connector
cover set (1 pc.)
[84-61-8505]
I/F cable for PAT-T Regulated
DC Power Supplies (1 pc.)
[91-88-7330]
LAN cable (1 pc.)
Straight type
Ferrite core for
26-core flat cable (1 pc.)
[96-01-0260]
Ferrite core for
20-core flat cable (1 pc.)
[96-01-0250]
Load input terminal cover set
(4 sets)
Covers, auxiliary bands
Operation manual
(English and Japanese,
1 of each)
[91-88-7330]
[96-01-0210]
Model
Description
Length
Quan
tity
TL10-PFX
DC power supply connection
cable
[Solderless terminal: M8–M10]
60 cm(+)
1 pc.
60 cm(-)
1 pc.
Electronic load connection
cable
[Solderless terminal: M8–M8]
60 cm(+)
1 pc.
60 cm(-)
1 pc.
DUT cable
(For connecting the DUT)
[Solderless terminal: M8–M10]
3 m(+)
1 pc.
3 m(-)
1 pc.
Sensing cable
(Voltage / temperature sensing
cable: already assembled)
3 m
1 pc.
Model
Description
Length
Quan
tity
SC07-PFX
I/F cable
For between a PFX2532 and PWR-01
Approx.
1 m
1 pc.
Cables required for system configuration
See
See
See
Содержание PFX2532
Страница 12: ...12 PFX2532 This page is intentionally blank ...
Страница 25: ...Connecting and Configuring Devices This chapter describes how to connect and configure the devices ...
Страница 62: ...62 PFX2532 This page is intentionally blank ...
Страница 71: ...Specifications This chapter provides the PFX2532 s specifications and outline drawing ...
Страница 96: ...96 PFX2532 This page is intentionally blank ...
Страница 141: ......