PFX2532 Electric Specifications
5
Specific
a
tions
Setting accuracy
Static/ Pattern
Constant
current
charge/
discharge
Range
1
1
The range varies depending on factors such as the connected DC power supplies and electronic loads
and the wiring configuration of the system.
0.000 A to 200.000 A
Accuracy
2
2
Ambient temperature at 18
°
C
to 28
°
C.
3
3
The external devices are controlled through software so that the measured values are equal to the
settings. The accuracy of the settings is the same as the measurement accuracy. Because this is
dependent on the control cycle, correct control may not be possible for a DUT (battery) with high
impedance or a DUT whose circuit is open.
Control cycle for constant current / constant voltage control is 1 ms and for constant cell voltage
control is 100 ms.
Resolution
1 mA
Constant
voltage
charge/
discharge
Range
1
60 V range
0.000 V to 60.000 V
6 V range
0.000 V to 6.000 V
Resolution
1 mV
Constant cell
voltage
Charge/
discharge
4
4
Can be set only when the optional Volt / Thermometer Unit OP02-PFX or OP03-PFX Voltmeter Unit is
installed.
Range
1
0.000 V to 20.000 V
Resolution
1 mV
Constant
power
discharge
Range
1
1 W to 12000 W
±(0.5 % of set +10 W)
5
5
The battery voltage is measured, and the control current (constant current control) is calculated from
the set power value through software calculation. The time required to process one calculation (from
the voltage measurement to the output setting) is approximately 1 ms.
Resolution 1 W
Pattern
6
6
The operating voltage range is 1 V or more (when the TL10-PFX is being used; regardless of whether a
bias DC power supply is being used).
Pattern
constant
current
Range
1
-200.000 A to 200.000 A (Negative values are
discharge currents)
Accuracy
Resolution
1 mA
Number of settings
10000 (Maximum number of steps)
Time width
Range
0.1 s to 9999.9 s (the time width per step)
Accuracy
±(0.05 % of set + 10 ms)
Resolution
100 ms
Pattern
constant
power
Range
1
-12000 W to 12000 W (Negative values are discharge
power)
Accuracy
7
7
With battery voltage of 2 V or more.
±(0.5 % of set + 10 W)
Resolution
1 W
Number of settings
10000 (Maximum number of steps)
Time width
Range
0.1 s to 9999.9 s (the time width per step)
Accuracy
±(0.05 % of set + 10 ms)
Resolution
100 ms
Содержание PFX2532
Страница 12: ...12 PFX2532 This page is intentionally blank ...
Страница 25: ...Connecting and Configuring Devices This chapter describes how to connect and configure the devices ...
Страница 62: ...62 PFX2532 This page is intentionally blank ...
Страница 71: ...Specifications This chapter provides the PFX2532 s specifications and outline drawing ...
Страница 96: ...96 PFX2532 This page is intentionally blank ...
Страница 141: ......