KIKUSUI Electronics Corp.
194
VOLT:PROT:LOW
Sets the UVP value.
For single-phase three-wire output and three-phase output, set the limits using phase
voltages.
This command is valid when using the UVP function (VOLT:PROT:LOW:STAT ON).
Command
[SOURce:]VOLTage:PROTection:LOWer <numeric>
[SOURce:]VOLTage:PROTection:LOWer?
Parameter
Value:
0 to +489.5
UVP value (The default value is 0)
Unit:
V
Settings are reset to default values when an *RST command is sent.
Example
VOLT:PROT:LOW 120.0
Response: NR3