KIKUSUI Electronics Corp.
188
VOLT:LTL
Sets the line AC voltage.
This command is valid for single-phase three-wire output.
This command is valid during three-phase output when the U-V phase difference is
120 (SYST:CONF:PHAS:UV 120) and the U-W phase difference is 240 (SYST:CON-
F:PHAS:UW 240).
If the signal source is set to external signal source (VOLT:EXT:EXTDC:SIGN:SOUR
EXT), this command is invalid.
This command is invalid when an external analog signal is used to control the voltage
or frequency (VOLT:EXT:FUNC:MODE VPR).
Command
[SOURce:]VOLTage:LTLine <numeric>
[SOURce:]VOLTage:LTLine?
Parameter
Value:
0 to 315.0 Line AC voltage in the single-phase three-wire output L
range
0 to 630.0 Line AC voltage in the single-phase three-wire output H
range
0 to 272.7 Line AC voltage in the three-phase output L range
0 to 545.5 Line AC voltage in the three-phase output H range
(The default value is 0.)
Unit:
V
Settings are reset to default values when an *RST command is sent.
Example
VOLT:LTL 173.0
Response: NR3
R9.91E+37 in the case of unbalanced phase or unbalanced voltage.