[SOURce:]VOLTage Command
PCR-WE Interface Manual
193
VOLT:OFFS:TRIG
Sets the DC voltage to change to when INIT:TRAN or a software trigger is sent.
This command is invalid when the combined value with the AC voltage is outside the
allowable range (L range: -222.5 V to 222.5 V, H range: -445.0 V to 445.0 V).
If the signal source is set to external signal source (VOLT:EXT:EXTDC:SIGN:SOUR
EXT), this command is invalid.
Command
[SOURce:]VOLTage:OFFSet:TRIGgered <numeric>[,(@chanlist)]
[SOURce:]VOLTage:OFFSet:TRIGgered?
Parameter
Value:
-222.5 to +222.5 DC voltage in the L range
-445.0 to +445.0 DC voltage in the H range
(The default value is 0.)
Unit:
V
Settings are reset to default values when an *RST command is sent.
Example
VOLT:OFFS:TRIG -10.5
Response: NR3