[SOURce:]VOLTage Command
PCR-WE Interface Manual
199
VOLT:RANG
Sets the voltage range.
If the AC voltage and DC voltage (including the value changed by a trigger) are set
within the H range, the voltage range cannot be set to L range.
This command is invalid when the output is on (OUTP ON).
Command
[SOURce:]VOLTage:RANGe[:UPPer] <numeric>
[SOURce:]VOLTage:RANGe[:UPPer]?
Parameter
Value:
157.5
L range (default)
315
H range
Settings are reset to default values when an *RST command is sent.
Example
VOLT:RANG 315
Response: NR3