SYST:CONF:PHAS:UOFF
Sets the absolute phase angle of the U phase relative to the reference phase.
This command is valid for three-phase output.
If the signal source is set to external signal source (VOLT:EXT:EXTDC:SIGN:SOUR
EXT), this command is invalid.
Command
SYSTem:CONFigure:PHASe:UOFFset <numeric>
SYSTem:CONFigure:PHASe:UOFFset?
Parameter
Value:
-360.00 to 360.00 Absolute phase angle (The default value is 0)
Unit:
DEG
Settings are reset to default values when an *RST command is sent.
Example
SYST:CONF:PHAS:UOFF 35.51
Response: NR3