[SOURce:]FREQuency Command
PCR-WE Interface Manual
165
FREQ:LIM:UPP
Sets the upper frequency limit.
If the signal source is set to external signal source (VOLT:EXT:EXTDC:SIGN:SOUR
EXT), this command is invalid.
The following relationship must be met: FREQ:LIM:LOW ≤ FREQ|FREQ:TRIG ≤ FRE-
Q:LIM:UPP
Command
[SOURce:]FREQuency:LIMit:UPPer <numeric>
[SOURce:]FREQuency:LIMit:UPPer?
Parameter
Value:
1.00 to 5000
Frequency (The default value is 5000)
1.00 to 500.0 on the 500 Hz limit model (The default
value is 500)
Unit:
HZ
Settings are reset to default values when an *RST command is sent.
Example
FREQ:LIM:UPP 70
Response: NR3