SYSTem Command
PCR-WE Interface Manual
253
SYST:CONF:FORM:PSAV:MOD
Sets all power modules to run using the power-saving function.
This command is invalid for the PCR1000WE/PCR2000WE/PCR3000WE2.
Command
SYSTem:CONFigure:FORMation:PSAVer:MODules <character_>[,<charac-
ter>]...
SYSTem:CONFigure:FORMation:PSAVer:MODules?
Parameter
<character>
The first parameter is the power module operating condition of the master unit.
The subsequent parameters are the power module operating conditions for slave unit
1 and later (for parallel operation only).
The number of parameters must be equal to the number of PCR-WE units, which in-
cludes the master unit and slave units.
Parameter details: {E|D}{E|D}{E|D}{E|D}{E|D}{E|D}...
(E|D) represents power module 0, power module 1, power module 2, and so on from
the left. This must be set the same as the number of slots that the PCR-WE has.
Value:
E
Power module operated
D
Power module not operated
The default value is EEEEEE (standalone, all modules operated).
Example
To operate the master unit
ʼ
s power modules 0 and 1 and the slave unit 1
ʼ
s power
modules 2 and 3 and set the maximum expected power to 24000 VA (6000VA 4
modules).
SYST:CONF:FORM:PSAV:MOD EEDDDD,DDEEDD
Response: Characters, [,Characters]...