5
Tattoo™
Screens - Spine Screen Foot Assembly
Assembly Instructions
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Flex and Spine Screen - Overview
Note:
Flex Screens ship mostly
assembled, except for when topper
accessories are specified. Spine
Screens ship without base raceway
trim and feet attached. Feet must
be assembled to the bottom of each
Spine Screen as they are unpacked.
Figure 1
Spine Screen
foot
1
/ -20 x 2”
T-30 Torx screws
4
pass-through
ankle
Detail A - Bottom View of Spine Screen
“NE” holes
face to center
1
/ -20 x 2”
T-30 Torx
screw
4
feet
( NE” mounting holes
facing towards the center
of the screen)
Detail B
pass-through
ankle
Spine Screen
height-adjustable glides
twisted in fully for
screen to be at their
lowest position)
foot
Note:
If Spine Screens are not being
assembled, go now to “Flex Screen
Configurations” instructions on
page 42.
Important:
If the Spine Screen
System is to be installed with New
York City electrical, proceed to the
Tattoo Screen System - New York
City Electrical Assembly Instruction
(KI-AI-000045) before proceeding
to "Spine Screen Foot Assembly"
instructions on this page.
Spine Screen Foot Assembly
1. Carefully lay Spine Screen flat onto a
soft, protective surface (Figure 1).
Note:
An “EL” and “NE” are
embossed on the bottom of each
foot, corresponding to wider and
narrower hole patterns respectively.
Only the wider “EL” holes are used
for mounting the feet to the Spine
Screen pass-through ankle. But, the
“NE” holes (narrower hole pattern)
are referenced below to orient inward
for correct installation of the foot.
Take care and follow the directions
below when positioning feet for
installation. If feet are not installed in
the correct orientation, screens will
not gang in-line with each other and
disassembly and correct re-assembly
will be required.
2. Orient each foot such that the wider
positioned “EL” mounting holes are
to the outside of the Spine Screen
unit and the narrower positioned
“NE” holes are positioned closer to
the center (Detail A), then position
each foot over the corresponding
mounting holes of the pass-through
ankle. Secure each foot to the
pass-through ankle using two
1
/
4
-20 x 2” T-30 Torx screws
(Figure 1 & Detail A).
3. Twist the height-adjustable glides
in clock-wise, fully to the bottom of
the foot. This will allow for upward
adjustment of the screen, if required
at the final installation location
(Figure 1 & Detail B).
Содержание Tattoo Flex Screen
Страница 1: ...Assembly Instructions Tattoo Screen System July 2019...
Страница 50: ...50 Tattoo Screens Assembly Instructions...
Страница 51: ...51 Tattoo Screens Assembly Instructions...