31
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™
Screens - Spine Screen Data
Assembly Instructions
Data Installation
Note:
Data cables must only be run
after all screens are mechanically
connected together, and after all
power has been installed.
Note:
A 45 degree data mounting
plate is required due to limited
space in the base raceway channel.
Cables, terminations and 45 degree
data mounting plates are customer
supplied.
1. Per the space-planning layout,
determine data jack locations
required in base wireway channels.
A standard cutout for data plates
in base raceway trim is provided
(Figure 33).
2. Data cables must be routed and
placed underneath the 10-wire rigid
wireway, in the bottom wireway
channel.
3. Route data wires from their source
and along the bottom wireway
channel to the desired data jack
locations (Detail QQ).
4. Align the holes of the 45 degree data
mounting plate with the base raceway
trim holes and secure with the
screws provided. Make all data jack
connections per the manufacturer’s
specifications.
5. After all data connections have been
made, install the base raceway trim
by engaging the base trim lip with
the bottom wireway channel
(Detail RR).
base
raceway
trim
45 degree
data mounting
plate
data mounting
plate screws
data jack
connector
Figure 33
Detail QQ
base
raceway
trim
45 degree
data mounting
plate
data
mounting
plate screws
data jack
connector
Detail RR
base
raceway
trim
base
trim lip
bottom
wireway
channel