146
Appendix D
Error Messages
Error Messages
O
47
OPEN measurement incomplete
This error occurs when the cable correction OPEN measurement is incomplete.
-321
Out of memory
The E4981A has insufficient memory to perform the requested operation.
P
1080
Power failed
Power unit hardware failure is detected.
Contact Keysight Technology’s Sales and Service Office or the company from which you
purchased the device.
-108
Parameter not allowed
The number of parameters is larger than required by the command. For example, although
the
:CREJ:LIM
command requires one parameter such as “
:CREJ:LIM 3
”, two
parameters are added to give “
:CREJ:LIM 0,3
”.
-112
Program mnemonic too long
The length of the header exceeds 12 characters. (Refer to IEEE488.2,7.6.1.4.1.)
Q
-350
Queue overflow
The queue contains a certain code other than the code that caused this error. This indicates
that an error has occurred due to insufficient space in the queue but has not been recorded.
-400
Query error
A comprehensive Query error has occurred for which the E4981A cannot detect further
details. This code simply indicates the occurrence of a Query error that is defined in
IEEE488.2,11.5.1.1.7 and 6.3.
-410
Query INTERRPUTED
This indicates the status that causes an “INTERRUPTED” Query error. (Refer to
IEEE488.1,6.3.2.3.) This error occurs, for example, when data byte (DAB) or GET is
received after Query but before the response has been completely sent.
-420
Query UNTERMINATED
This indicates the status that causes an “UNTERMINATED” Query error. (Refer to
IEEE488.2,6.3.2.) This error occurs, for example, when the E4981A is specified as a talker
and an incomplete program message is received.
-430
Query DEADLOCKED
This indicates the status that causes a “DEADLOCKED” Query error. (Refer to
IEEE488.2,6.3.1.7.) This error occurs, for example, when both input and output buffers
become full and the E4981A cannot continue processing.
Содержание E4981A
Страница 1: ...Keysight E4981A 120 Hz 1 kHz 1 MHz Capacitance Meter Service Guide ...
Страница 2: ......
Страница 13: ...Contents 11 L 145 M 145 N 145 O 146 P 146 Q 146 R 147 S 147 T 147 U 148 Warning Message 149 ...
Страница 14: ...12 Contents ...
Страница 70: ...68 Chapter4 Troubleshooting Performance test failure troubleshooting ...
Страница 84: ...82 Chapter5 Replaceable Parts Replaceable Parts List Front Panel Figure 5 12 Front Panel ...
Страница 96: ...94 Chapter6 Replacement Procedure 3 4 Rack Module Top Replacement Figure 6 3 Screw Fastening Sequence ...
Страница 98: ...96 Chapter6 Replacement Procedure PSU Deck Assembly Removale Figure 6 4 PSU Deck Assembly Removal ...
Страница 100: ...98 Chapter6 Replacement Procedure PSU Assembly Replacement Figure 6 5 PSU Assembly Replacement ...
Страница 102: ...100 Chapter6 Replacement Procedure Front Chassis Assembly Removal Figure 6 6 Front Chassis Assembly Removal ...
Страница 104: ...102 Chapter6 Replacement Procedure Front Panel Assembly Removal Figure 6 7 Front Panel Assembly Removal ...
Страница 108: ...106 Chapter6 Replacement Procedure Interface Board Assembly Replacement Figure 6 10 Screw Fastening Sequence ...
Страница 118: ...116 Chapter6 Replacement Procedure Power Inlet Assembly Replacement Figure 6 17 Power Inlet Assembly Replacement ...
Страница 122: ...120 Chapter6 Replacement Procedure Inverter Assembly Replacement Figure 6 20 Inverter Assembly Replacement ...
Страница 124: ...122 Chapter6 Replacement Procedure Display Support Removal Figure 6 21 Display Support Removal ...
Страница 132: ...130 Chapter7 Post Repair Procedures Post Repair Procedures ...
Страница 138: ...136 AppendixB Firmware Update Update the E4981A firmware using USB cable ...
Страница 139: ...137 1 Chapter Title 2 Chapter Title 4 Chapter Title 5 Chapter Title C Power Requirement C Power Requirement ...
Страница 142: ...140 AppendixC Power Requirement Power Requirements ...