TRIGger:TRANsient:SOURce IMMediate|BUS
TRIGger:TRANsient:SOURce?
Sets the trigger source for changing the setting value after
. Specify IMMediate (the default)
to start the measurement immediately, or BUS to wait for a software trigger (*TRG, TRIG, or
TRIG:TRAN).
Parameter
Typical Return
IMMediate|BUS IMM or BUS
Set the trigger source to BUS:
TRIG:SOUR BUS
This parameter is set to IMMediate at power-on or after *RCL or *RST.
3 SCPI Programming Reference
158
Keysight AC6800B Series Operating and Service Guide