![Keithley 2110 Скачать руководство пользователя страница 36](http://html.mh-extra.com/html/keithley/2110/2110_reference-manual_661855036.webp)
Model 2110 5½ Digit Multimeter Reference Manual
Section 2: General overview
2110-901-01 Rev. C/August 2013
2-17
Keys, menus, and selection
Description
CONFIG (MENU)
Press
CONFIG (MENU)
to select the menu.
SET ADC
Select to configure autozero. Refer to
(on page 3-38) for
details.
AUTO ZERO
Selects the autozero operation. Refer to
(on page 3-38) for
details.
ON
Turns the function or operation on.
OFF
Turn the function off.
TRIG SYS
Access trigger system settings. Use ► and ◄ keys to display
additional selections.
READ HOLD
Set the sensitivity band of the reading hold function. If set, it will hold
the stable reading and trigger a beeping sound. Refer to
(on page 3-35) for details.
STORE RDGS
Set number of readings to be stored.
DELAY
Access delay time settings for the trigger. Refer to
page 3-34) for details.
AUTO
Select auto delay time for the trigger. AUTO is the default. After
selecting AUTO, the menu structure will close.
MANUAL
Select manual delay time, and then select the delay time.
SAMPLE CNT
Select number of samples per trigger.
TRIG CNT
Select number of triggers.
SYSTEM
Access system settings. Use ► and ◄ keys to display additional
selections.
SCPI ERR
Check the error queue. Refer to
(on page 6-3) for
information about error queue.
INIT MODE
Check the initial mode settings. Refer to
(on page 2-23) for details.
DEFAULT SET
Recall the factory settings. Refer to
(on page 1-6)
for details.
SAVE DATA
Save the current settings as the power-on state. Only the primary
and secondary measurement function, range, resolution, and math
functions are saved. Refer to
Selecting the initial operating mode
(on page 2-23) for details.
SYSTEM VERSION
Display system version. Refer to
2-24) for details.
INSTRUMENT INFO
Display instrument manufacturer and model number.
SERIAL
Display instrument serial number.
DISPLAY
Access display settings. Refer to
Turning off measurement display
(on page 2-21) for details.
ON
Turn display on.
OFF
Turn display off.
BEEP
Access beeper settings. Refer to
page 2-22) for details.
ON
Turn beeper on.
OFF
Turn beeper off.
SELF TEST
Perform a self-test and display results. Refer to
(on page 6-2) for details.
LANGUAGE
Access remote command language settings. Refer to
(on page 2-23) for details.
DEFAULT
Set default language. The default language is: Model 2110 SCPI.
COMPATIBLE
Set to SCPI-compliant DMM language mode.