Door Definition
This feature is used to define the doors of the system (door type,
unlocking schedule, etc).
Field Definition
Door - COM2:01:01
The door address is a physical address consisting of the serial
port, the physical address of the controller *, and the physical
address of the doors (1 or 2). The door address cannot be modified
unless the controller serial port setting is modified at which time
the door address is automatically changed by the system.
“S
EE
SECTION
11
IF
YOU
ARE
USING
KT-200
CONTROLLERS
”
Door
The door label consists of 12 alphanumeric characters or less and
is used to identify the door within the system.
Door name
The door name consists of 30 alphanumeric characters or less. It
also gives detailed information concerning the door i.e.: Front
Entry Door.
Door type
Indicates if the door is considered as an entry or an exit. For doors
that have readers on each side, select ENTRY for the outer reader
and EXIT for the inner reader (must be used for Anti-Passback).
Reader and/or keypad
Indicates how access to the door is controlled: by a reader, a
keypad or both.
Locked state
Selects the operating mode of the lock installed on the door.
“DEENERGIZED TO LOCK” is used for doors with fail-secure
devices such as door strikes and “ENERGIZED TO LOCK” is used
for doors with fail-safe devices such as mag locks.
Unlock time on access
The time during which the door is unlocked following a valid card
reading or a valid request-to-exit (REX). Maximum time allowed is
4 minutes and 15 seconds.
Door open time on access
The time period during which a door can remain open following a
valid access or a REX. Applies only to a controlled door monitored
with a contact. Maximum time allowed is 4 minutes and 15 seconds.
Unlock schedule
The door will automatically unlock according to this schedule. To
view other defined schedules, click on the pick list.
Keypad schedule
Used with doors defined as “Reader/keypad”. This is the sched-
ule according to which it will be necessary to enter a PIN code at
the keypad after presenting a valid card. Applicable only to those
card users set to “Must use PIN” in Card definition.
Display picture on access
This option allows you to automatically display the user’s picture
when an access event is generated.
Buttons
Allows for activation of a selected relay, when the chosen event
is reported. The following events can be selected to activate a
relay: door forced, door open too long, door still opened, access
granted, card traced, invalid card state, bad access level card, other
access denied and duress function.
If you click on the Events button from the door definition screen,
the system will display:
Select the relays to be activated when the selected event occurs.
Allows to enter more information concerning the door. If you
select the “More” button from the door definition screen, the
system will display an addtional screen for the chosen door.