Relay Definition
This screen is used to define when relays will be triggered
according to schedule and what they will trigger.
Field Definition
Relay - COM2:01:01
The relay address is a physical address consisting of the serial
port, the physical address of the controller and the physical
address of the relay. *
“S
EE
SECTION
11
IF
YOU
ARE
USING
KT-200
CONTROLLERS
”
Relay
The relay label is composed of 12 alphanumeric characters or less.
Relay name
The relay name is composed of 30 alphanumeric characters or less.
It provides additional information concerning the relay.
Normal state
Select the state of the relay when no event, schedule or manual
operation is activating it (deactivated or activated).
Automatic activating schedule
Select a schedule according to which the relay will automatically
be activated.
Force normal state schedule
The schedule according to which the relay will be forced to remain
in its normal state. Only a manual operation could change the
status of the relay.
Activation period
Activation period is set in hours, minutes and seconds. It’s the
time period during which the relay will be momentarily activated.
Input Definition
This feature is used to define inputs (monitoring schedule, relay
activated by input, etc).
Field Definition
Input - COM2:01:01
The input address is a physical address consisting of the serial
port, the physical address of the controller and the physical
address of the input (1 to 8 - without expansion module).*
“S
EE
SECTION
11
IF
YOU
ARE
USING
KT-200
CONTROLLERS
”
Input
The input label is composed of 12 alphanumeric characters or less.
The label is used to identify the input in the system.
Input name
The input name is composed of 30 alphanumeric characters or less.
Normal condition
Set to either normally open or normally closed.
Input Definition -
Field Definition
Monitoring schedule
Schedule according to which the system will supervise the con-
dition of the input. When the schedule is valid, a changed
condition of the input generates either a “Input in alarm” or “Input
restored” event.
Alarm loop response
Delay in hundredths of a second from 10 to 65535 indicating the