Workstation Configuration
This feature is used to define the workstation’s parameters.
Field Definition
Time:
Enable time change
Click here to activate the time change mode. Set the dates for
automatic time change.
Daylight savings time
The Daylight savings time date change can be entered here and
the system will automatically, at 2:00 am, advance the time to 3:00
am on the first Sunday of April.
Standard time
The Standard time date change can be entered here and the system
will automatically, at 2:00 am, set back the time to 1:00 am on the
last Sunday of October.
Note : It is very important to enter the correct year.
General:
Keypad time-out delay
The keypad time-out delay is set in seconds for a maximum of 127
seconds which represents the time allowed for a user to begin
entering his or her personal identification number (PIN) at a
keypad.
Keypad inter-digit delay
The keypad inter-digit delay is set in seconds, up to two minutes.
It represents the maximum delay permitted between each selection
of a keypad key by a user.
Automatic logout delay
The Automatic logout delay is the predetermined time set after
which the system automatically logs out the operator who is
inactive. The time is entered in hours, minutes and seconds. This
feature provides additional security to prevent access to the
system by an unauthorized person.
Card format
The card format setting determines how the card numbers will be
represented throughout WinPass. Usually displays 8 digits, but
some readers offer the 16-digit format.
B u t t o n s
B u t t o n s
B u t t o n s
B u t t o n s
B u t t o n s
“Port Settings” button
Select the baud rate speed that will be used to poll the door
controllers. There are four choices: 1200, 2400, 9600 and 19200.
Setting a lower poll rate on the controllers may correct some
communication problems due to induction or faulty cabling.
Note: To select the COM port on which the controllers are
connected to the host computer, refer to Section 5 under control-
ler definition menu under “More” button.
Note: When selecting the baud rate in the software, the KT-300
will automatically adjust to the selected rate.*
“S
EE
SECTION
11
IF
YOU
ARE
USING
KT-200
CONTROLLERS
”
THE CONFIGURATION MENU TOOLBAR