Fig. 21 Jumper cable connection diagram
A
Machine batteries (receiving battery)
B
Assisting vehicle batteries (externally pro‐
vided battery)
1
Negative pole clamp (black/blue) on bat‐
tery of assisting vehicle
2
Positive pole clamp (red) on battery of as‐
sisting vehicle
3
Positive pole clamp (red) on machine bat‐
tery
4
Negative pole clamp (black/blue) on ma‐
chine earth
5
Bare metal point on the airend (earth)
Complying with safety notes:
1.
Fault in jump-start process!
➤ Connect batteries of the same nominal voltage only.
➤ Ensure that machine and assisting vehicle do not touch.
➤ Switch off all consumers prior to connecting and disconnecting the batteries.
➤ Only use battery jumper cables of sufficient diameter and with insulated terminal clamps.
➤ Observe the instructions provided with the battery jumper cables.
➤ Keep jumper cables away from rotating parts.
➤ Avoid short-circuits due to incorrect poling and/or bridging with tools.
➤ Do not bend over the batteries when attaching jumper cables.
➤ Do not attempt to start the machine if its battery is frozen. Allow the battery to thaw first!
➤ Do not try to start the machine with a boost charger.
2. Comply with the safety instruction listed when jump-starting and using starter batteries.
Preparations:
1. Park the assisting vehicle in close distance to the engine, without their bodywork coming into
contact with each other.
2. Stop the engine of the assisting vehicle.
3. Open the accesses to the batteries (remove maintenance panels/bonnet and pole caps).
4. Switch off all power consumers.
7
Initial Start-up
7.4
Low-temperature operation (winter)
No.: 901783 08 USE
Operator Manual Portable Rotary Screw Compressor
MOBILAIR M82 SIGMA CONTROL SMART