Code Meaning
Remedy
see chapter
2202 Maintenance - change compressor cooling oil
(1000h)
Change the cooling oil.
h - operating hours
Tab. 92 Maintenance messages and required actions
10.2.2 Concluding the maintenance
Resetting the maintenance interval counter
Precondition Maintenance is carried out
➤ Reset the maintenance timer as described in the separate operating manual for the
SIGMA CONTROL SMART controller, chapter “Reset maintenance timer”.
10.3 Maintenance schedules
10.3.1 Logging maintenance work
The maintenance intervals given are those recommended for KAESER original components
with average operating conditions.
➤ In adverse conditions (e.g. oil and filter changes), perform maintenance work at shorter
intervals.
Adverse conditions are, e.g.:
■ poor fuel quality
■ high/low temperatures
■ a lot of dust
■ frequent use
➤ Adjust the maintenance intervals with regard to local installation and operating condi‐
tions.
➤ Logging all maintenance work.
This enables the frequency of individual maintenance tasks and deviations from our recom‐
mendations to be determined.
Further information A list is given in chapter 10.16.
10.3.2 Preventive maintenance
Preventive maintenance begins with a daily check of the machine.
10 Maintenance
10.3 Maintenance schedules
112
Operator Manual Portable Rotary Screw Compressor
MOBILAIR M82 SIGMA CONTROL SMART