➤ Attach the following notice on the instrument panel to inform of the decommissioning measures
taken.
Attention!
1. The machine is decommissioned.
2. It is filled with preserving oil.
3. For recommissioning:
■ Take measures for recommissioning the compressor after a long period of storage.
■ Recommission according to service manual.
Date / signature
Tab. 108 Text for the long-term decommissioned and storage information notice
➤ Store in a dry place with constant temperatures.
12.2 Transport
Precondition Machine switched off and locked off
(«battery isolating switch» off)
The machine is fully vented, the pressure gauge reads 0 psig.
Machine is cooled down.
All compressed air consumers are disconnected.
All connecting lines and hoses disconnected and removed.
Any loose or movable parts that may fall when transporting are removed or secured.
12.2.1 Safety
Allow transportation only by personnel trained in safely dealing with motor vehicles and the
transporting of goods.
1.
There is danger of being run over or crushed by an overturning vehicle.
Death or serious injury can result from being crushed or run-over by a machine being towed.
➤ Riding on the machine while it is being towed is strictly forbidden.
2. Make sure the danger area is clear of personnel.
12.2.2 Transporting the machine as trailer
➤ Note the instructions in the separate document "Chassis Operating Manual" regarding the topic
"transport of the machine as trailer".
12.2.3 Transporting the machine by crane
Precondition The machine is standing firm and level.
The machine is switched off.
The machine has cooled down.
12 Decommissioning, Storage and Transport
12.2 Transport
No.: 901783 08 USE
Operator Manual Portable Rotary Screw Compressor
MOBILAIR M82 SIGMA CONTROL SMART