10.15.6 Option ga
Maintaining the generator drive belt
Correct belt tension is extremely important for the function of the generator and the operational life
of the belt itself. The lifespan of the drive belts is affected by belt tension.
■ Slack V-belts can cause belt slip and damage to the belts.
■ Over-tight belts stretch and fatigue quicker. Over-tight belts also place unnecessary stress on
bearings and shorten their life.
Material Wrench
Spare parts (if required)
Precondition The machine is switched off.
The machine is fully vented, the pressure gauge reads 0 psig.
The machine has cooled down.
All compressed air consumers are disconnected and the air outlet valves are open.
The «battery isolating switch» is turned off.
Beware of rotating pulleys and moving belts.
Touching the moving drive belt may result in severe bruising or even loss of limb or extremi‐
ties.
➤ Check the belt only when the compressor is shut down.
➤ Never run the machine without a belt guard.
➤ Open both doors.
10 Maintenance
10.15 Maintenance for Optional Items
No.: 901783 08 USE
Operator Manual Portable Rotary Screw Compressor
MOBILAIR M82 SIGMA CONTROL SMART
179