13.9 Option ga
Maintenance tasks for the generator
In order to ensure a safe operation of the machine, the generator must be inspected once every
year by a trained and authorized electrician.
Have the following tasks performed by a specialist electrician or an authorized KAESER service
representative:
■ Inspection of the generator and generator control cubicle for mechanical damages.
■ Inspection of the protective conductor.
■ Measurement of the dielectric resistance.
■ Measurement of the substitute leakage current.
■ Inspection of generator functionality.
■ Inspection of the proper functioning of the generator fan and cleaning, if required.
■ Cleaning the cooling air apertures.
■ Check all screwed connections on the generator and control box and tighten if necessary.
■ Check covers and power socket caps for damage and good sealing.
■ Check that all warning and other labels are complete and undamaged.
13.10 Oil-injected MOBILAIR service intervals
Maintenance strategy 000510 (1x service per year):
Package sequence
A
B
A
B
A
C
from the beginning
Years
1
2
3
4
5
6
Tab. 113 Service maintenance package - (1x service per year)
Change intervals apply to favourable ambient conditions, such as good fuel quality, cool to
medium ambient temperatures, low humidity and low to medium dust exposure.
13 Annex
13.9 Maintenance tasks for the generator
No.: 901783 08 USE
Operator Manual Portable Rotary Screw Compressor
MOBILAIR M82 SIGMA CONTROL SMART
397