Material Spare part
Cleaning cloths
Wrench
Precondition The machine is switched off.
The machine is fully vented, the pressure gauge reads 0 psig.
The machine has cooled down.
All compressed air consumers are disconnected and the air outlet valves are open.
The «battery isolating switch» is turned off.
Fig. 67 Changing the oil separator cartridge
1
Control air line union nut
2
Oil scavenge pipe (screwed to the cover)
3
Oil scavenge pipe union nut (lower fitting,
screwed to the dirt trap)
5
Air pipe
6
Pipe fitting
7
Cover
8
Fastening screw
9
Control valve
10
Solenoid valve plug
11
Gasket
12
Metal clip
13
Oil separator cartridge
14
Pressure transducer
➤ Open the right-hand access door.
Changing the oil separator cartridge:
1. Unscrew the union nuts
1
and
3
and place the components with connections carefully to one
side.
2. Pull out the plugs at the connection cables of the solenoid valves
10
and withdraw the cable.
3. Pull out the plug to the sensor
14
and withdraw the cable.
10 Maintenance
10.6 Compressor Maintenance
No.: 901783 08 USE
Operator Manual Portable Rotary Screw Compressor
MOBILAIR M82 SIGMA CONTROL SMART
155