Item Sign
Designation
Function
Background LED
1
–
Indicator field or
display
Graphic display
–
2
«Up» and «Down»
keys
■ Scrolls upwards or downwards
through the menu options.
■ Enter settings.
■ Change values.
■ Switch between menu pages.
–
3
«Enter» key
■ Jumps to the selected menu
option.
■ Finish an entry.
■ Activate the input.
■ Acknowledges/resets mainte‐
nance tasks.
■ Returns to the superordinate
menu item (quick touch)
■ Closes the menu (press for at
least two seconds)
–
4
Key
«LOAD/IDLE»
Toggles the compressor between
LOAD and IDLE operating modes.
Flashes when ready for
switching to LOAD
mode.
Continuous light when
the machine is running
under LOAD.
5
«STOP» key
■ Stops the machine.
■ Acknowledges/resets mainte‐
nance tasks.
Continuous light when a
fault has occurred.
6
«START» key
Start the machine.
Flashes when ready to
start.
Lights continuously,
when the engine is run‐
ning.
Tab. 61 Instrument panel keys and displays
Further information For more information about the controller's functionality, please see the separate
SIGMA CONTROL SMART user manual.
4.7 Exhaust gas after-treatment
The exhaust from a diesel engine contains invisible particles that are dangerous to health.
State-of-the-art engine technologies are used to reduce the emission of pollutants and to meet the
tighter exhaust standards.
For a proper balance, all parameters affecting combustion must be optimally adjusted to each oth‐
er. In interaction with injection and turbo-charging in particular, the exhaust gas recirculation allows
for combustions with significantly less nitrogen oxides.
4
Design and Function
4.7
Exhaust gas after-treatment
50
Operator Manual Portable Rotary Screw Compressor
MOBILAIR M82 SIGMA CONTROL SMART
No.: 901783 08 USE