Product Code : TGBv6.1 / November 2011
open each sash and fit the grub screws into
the inside hole on the outer hinge.
Fit the door handles and cylinder.
NB: To operate the locking mechanism
the handle must be lifted to allow the key
to turn the cylinder.
Ensure that the gap between the door
sashes is parallel. When set correctly the
gap between the doors will be 14mm.
Adjusting the Hinge
Vertical adjustment of each sash can be
achieved by inserting the 5mm Allen key into
socket 1 in the top of the outer frame hinges
and turning it clockwise to lift the door sash.
A maximum lift of 4mm can be achieved.
Horizontal (front to back) adjustment can
obtained by inserting the 5mm Allen key into
socket 2 in the top of the outer frame hinges
and turning 90º in either direction to adjust
the compression of the door sash. (N.B The
hinge pin grub screw will need to be
removed to allow this adjustment).
Horizontal (left to right) adjustment of the
sash can be achieved by use of socket 3
located on the end face of the sash hinge
cover (above). Insert the 5mm Allen key into
the socket of the hinge and turn clockwise to
move the sash inwards or anti-clockwise to
move the sash outwards, Approximately
4mm adjustment can be obtained in either
direction.
When content that the door sashes are
correctly adjusted, fit the outer hinge cover
caps.
1
2
3