Page 45
Garden Building
Installation Guide
Product Code : TGBv6.1 / November 2011
As the lug is already attached to the glazing
bar, screw the horizontal threaded tie bar
rod into the clevis.
Once the rod has been attached to the
clevis, the clevis can be fixed to the lug by
means of the M10 nut and bolt. Attach both
tie bar rods on the left and right sides of the
conservatory in this way.
With the vertical tie bar rod and the two
horizontal tie bar rods in place, raise them
all together towards the centre and thread
the ends of the tie bar rods through the
holes in the 3 way tie bar centre boss.
Raise the tie bar centre boss until the three
rods protrude into the boss.
When the tie bar centre boss assembly is in
place, thread on the M10 tie bar centre boss
locking nuts. Check the horizontal tie bar
rods for level before tightening the M10 tie
bar centre boss locking nuts fully.
When all tie bar poles are in position and
connected to all pole connectors, glazing bar
lugs and ridge connection, you can now
tighten the M10 tie bar centre boss locking
nuts fully ensuring that the horizontal tie bar
poles are tight fitting.