Page 16
Garden Building
Installation Guide
Product Code : TGBv6.1 / November 2011
Note: Some sections may require joining
by using in-line sill connector (C110).
Ensure that the external 90° sill connector
(C108) is silicone sealed on all contact
surfaces: top, bottom and sides.
Fix all sill connectors (C108/C110) to
150mm sill (PA1) with 3.9 x 16mm
reinforcing screws (SC025) as shown below.
IMPORTANT: Time spent getting the base
sill layout correct will save time later in
the installation, as paying attention to the
base sill dimensions, positioning, and
making sure it is level will ensure the
correct fitting of the rest of the
conservatory.
Lay the 150mm sill (P106) in position and
using your roof plan (located with your check
list), ensure that dimensions A and B are
consistent across the entire width and
projection and that both diagonals (C) are
equal.
Once level and in the correct position, using
the relevant drill bits, drill through the
150mm sill (P106) and into the base to at
least 100mm deep.