58
MAINTENANCE
QUADRIJET NONDRIP QUADRUPLE NOZZLE HOLDER
- After prolonged use, it may be necessary to service the nondrip valve. Refer to the drawing and table below.
PROBLEM
CAUSE
CORRECTION
- Impurities on the diaphragm.
- Rupture of the diaphragm.
- Rupture of the diaphragm followed by
chemicals buildup.
- Nut (1) not tightened properly.
- Remove and clean the diaphragm
- Replace the diaphragm
- Replace the diaphragm and clean the
plunger assembly
- Tighten the nut (1).
Valve
does
not seal.
- Seal (2) missing.
- Seal (2) damaged.
- Nut (1) not tightened properly.
- Fit the seal (2).
- Replace the seal (2).
- Tighten the nut (1).
Leakage between
the core and nozzle
holder.
- Packing ring (3) missing.
- Packing ring (3) damaged.
- Part (4) not tightened properly.
Leakage through the
connection with the
spray tube.
- Fit the packing ring (3).
- Replace the packing ring (3).
- Tighten the bolts of the part (4).
Leakage through the
nozzle holder and
the nozzle (cap with
thread)
- Nut (5) not tightened properly.
- Base of filter (6) damaged.
- Tighten the nut (5).
- Replace the filter (6).
NOTE: Before starting to spray, disassemble and clean the plunger assembly.
NOZZLES
- Clean the nozzles daily or whenever there is a failure in the spray.
ATTENTION: The flat fan nozzle has
red seal made of a material subject to
crush to facilitate sealing.
Therefore the use of threaded nozzle
cap is not recommended.
CONE NOZZLE
FLAT FAN NOZZLE
Seal
Leakage through the
nozzle holder with the
nozzle.
- Quick fitting nut not fitted properly.
- Packing ring (7) damaged.
- Base of filter (8) damaged.
- Fit the quick fitting nut.
- Replace the packing ring (7).
- Replace the filter (8).
1
3
2
4
8
7
5
6
core
diaphragm
nozzle holder