item Controller BL 1-04 /C
― Product manual
56
LAPP KABEL ÖLFLEX CLASSIC 110
Device type
Cable type
Specification (L, N, PE)
Circuit breaker
BL 4102-C
3 G 1.0
3 x 1,0 mm² (AWG 18)
B 10
BL 4104-C
3 G 1.0
3 x 1,0 mm² (AWG 18)
B 10
9.4 BL 1-04 /C: Connector: motor [X6]
Configuration on the device [X6]
Weidmüller SL 5.08HC/09/90G 3.2SN BK BX
Mating connector [X6]
Weidmüller BLF 5.08HC/09/180 SN BK BX
Pin assignment: motor with a motor temperature sensor
1
2
3
4
5
6
7
8
9
back panel of
control cabinet
WEIDMÜLLER
BLF 5.08HC/09/180 SN BK BX
Pin assignment: motor with a motor temperature sensor
U
V
W
PE
MT +
MT - / DSL -
BR +
BR -
DSL +
connector housing
motor housing
Figure 22: Pin assignment: motor connector (motor temperature sensor) [X6]
Pin
Name
Specification
1
U
Motor phase U
2
V
Motor phase V
3
W
Motor phase W
4
PE
Protective earth conductor of the motor
5
MT+
Motor temperature
6
MT-/ DSL-
Motor temperature sensor -
7
DSL+
8
BR+
Holding brake +
9
BR-
Holding brake -