29
item Controller BL 1-04 /C
― Product manual
Figure 12: "Error management" window
You can use this window to define the reaction of the servo drive in the event of an error. Different responses can be assigned
to every individual group. First select the group (by clicking) and then assign the responses. The following list shows the
responses with a rising priority.
Entry into buffer:
The event will simply be saved in the error buffer. The event will not be displayed, and the application contin
-
ues to run without being affected by the event.
Warning:
The event will be displayed briefly on the seven-segment display of the servo drive.
Disable servo drive:
The application will be stopped by way of the emergency stop ramp.
Stop at maximum stage immediately:
The drive will be stopped with maximum current.
Disable power stage immediately:
Some of the events are so serious that certain responses cannot be deselected. In this
case, the associated checkboxes are greyed out.
The configuration always applies to an entire group of errors. It is not possible to apply it to individual events.