5.2 ALARMS
When the machine is in Stop mode, the display shows a flashing alarm if it has not been reset
after its tripping or a steady on alarm if it has been reset.
E.g.
Alarm MA Inv.
To delete the warning message, press Decrease key.
If the alarm will not reset, this means it is still active.
Alarm table:
Display
Description
Alarm MA Inv.
Beater Inverter
Check beater inverter conditions and replace it if necessary. This alarm
triggers machine Stop.
Alarm TEC
"TEC" temperature probe switched off or short-circuited.
Check TEC temperature probe and replace it if necessary.
If the alarm occurs in Granita mode, the machine sets to Stop and it is not
possible to access Granita until the alarm is reset.
If the alarm occurs during Ice Cream Freezing, the pre-cooling phase is
by-passed.
The alarm message is visible only in Ice Cream Freezing and Granita
functions; it can be reset with the Decrease key and it will be displayed
again upon next Ice Cream Freezing or Granita cycle.
MA Comm. Error
Communication with Beater
Check MA Modbus connection cable
This alarm triggers machine Stop.
Spigot Door Open
The spigot door is open
This alarm triggers machine Stop and is automatically reset when spigot
door is closed.
Pressure Switch
Safety pressure switch tripping
This alarm disables the compressor.
If pressure switch trips 3 times in a row or if it stays open for 2
consecutive minutes, the machine sets to Stop. The display reads
“Pressure Switch”.
Check the inlet and outlet water pipes to make sure that water can flow
freely when the compressor is operating. For machines with air-cooled
condensers, it is necessary to make sure that the condenser fan is running
while the compressor is switched on, or that the air-cooled condenser
is not clogged; if this is the case, clean the condenser with a blast of
compressed air.
Overload RTC
Overload RTC
Check compressor motor absorption. This alarm triggers machine Stop.
When Compressor inner protection is reset, the message on the display
can be reset by pressing the Decrease button.
Timeout Prd
Timeout Prod (Cooling fault).
It is triggered when the machine cooling is faulty. If compressor remains
on continuously for over 15', during freezing, and HOT does not reach
a (fixed) Discriminant value, the machine sets to Stop with displayed
“Timeout Prd” alarm. It can be reset by pressing any button.
One of the possible causes for this type of problem could be no gas in the
system.
5.2.1 B
lackout
In case of temporary blackout, at power return, the machine is set to STOP mode.