7.2 WATER COOLING
In the case of water-cooled machines, water must be drained from condenser circuit at the end
of the season in order to avoid troubles in the event that the machine is stored in rooms where
temperature may fall under 0°C.
- Slide out inlet and outlet pipes from their seats and let water flow out from circuit by starting
the machine for a few seconds.
7.3 AIR COOLING
Clean condenser, periodically, so as to remove dust, paper and whatever prevents air from
circulating.
For cleaning, use a brush with long bristles or a bolt of compressed air.
WARNING!
When using compressed air, be careful and use
personal protective equipment in order to avoid accidents;
wear protective goggles!
WARNING!
Never use sharp metal objects to carry out this operation; the correct operation of a
refrigeration system largely depends on how clean the condenser is.
NOTE:
For machines equipped with air-cooled and water-cooled condenser follow the instructions of
paragraphs 7.2 and 7.3.
7.4 ORDERING SPARE PARTS
In the event of breaking or wear of one or more parts, request the new ones directly to an
ICETEAM
1927
Engineer, always detailing machine type and serial number printed on identification plate
located on the back of the machine.
WARNING
Before using spare parts and/or supplied parts intended to come into contact with the
product on the machine, it is absolutely necessary to clean and sanitize them as indicated
in sec. 6 of this manual
Fig. 31
Содержание ICETEAM 1927 STARGEL 4
Страница 8: ...8 Stargel 4 Stargel 4 2018 03 Rev 00 EN...
Страница 18: ...18 Stargel 4 Stargel 4 2018 03 Rev 00 EN...
Страница 36: ...36 Stargel 4 Stargel 4 2018 03 Rev 00 EN...