Operation Manual of INVT CHS100 AC Servo Drive 6 Detailed parameter description
85
3:57600bps;
4:115200bps.
Function
code
Name
Unit
Range
Default
Mode
Pc.23
Communication parity
mode
- 0~17 0 P.S.T
0: None (8, N, 1) for RTU;
1: Even (E, 8, 1) for RTU;
2: Odd (8, O, 1) for RTU;
3: None (8, N, 2) for RTU;
4: Even (E, 8, 2) for RTU;
5: Odd (O, 8, 2) for RTU;
6: None (N, 7, 1) for ASCII;
7: Even (E, 7, 1) for ASCII;
8: Odd (O, 7, 1) for ASCII;
9: None (N, 7, 2) for ASCII;
10: Even (E, 7, 2) for ASCII;
11: Odd (O, 7, 2) for ASCII;
12: None (N, 8, 1) for ASCII;
13: Even (E, 8, 1) for ASCII;
14: Odd (O, 8, 1) for ASCII;
15: None (N, 8, 2) for ASCII;
16: Even (E, 8, 2) for ASCII;
17: Odd (O, 8, 2) for ASCII;
Function
code
Name
Unit
Range
Default
Mode
Pc.24
Communication
response delay time
ms 0~200 0 P.S.T
Communication response delay time means the interval time from the end of the data
received by the subordinate machine (the machine means the servo drive) to sending
of response data by the upper PC. If the response delay time is shorter than the
processing time of the system, the response delay time will take the system processing
time as final. If the response delay time is longer than the processing time of the