Operation Manual of INVT CHS100 AC Servo Drive Appendix B
129
Appendix B: List of function parameters
P – position mode; S – speed mode; T – torque mode.
The function codes prefixed with sign “*” indicate the setting of these parameters can
only take effect after the system resets, restarts, or control circuit is powered off and
repowered.
The function codes prefixed with sign “#” indicate these parameters can only be
effectively set when it is stopped.
B.1 PA group parameters (Basic parameters)
Function
code
Name
Unit
Range
Default
Mode
PA.00
Parameter modification
operation locking
- 0~1 0
P.S.T
*PA.01 Mode
selection - 0~5 1
P.S.T
PA.02
Default monitored
parameters
- 0~26 0
P.S.T
PA.03
Internal servo enabling
-
0~1
0
P.S.T
#PA.04
Numerator of the 1st
electronic gear
- 1~65535 1
P
#PA.05
Denominator of the 1st
electronic gear
- 1~65535 1
P
*PA.06
Pulse input form
-
0~2
0
P
- 0~1 0
PA.07
Speed command
selection/speed limit
selection
- 0~1 0
S
.
T
- 0~1 0
PA.08
Torque command/torque
limit selection
- 0~1 0
P.S.T
PA.09
Internal speed/speed limit 1 r/min
-5000.0~5000.0
100.0
S.T
PA.10
Internal speed/speed limit 2 r/min
-5000.0~5000.0
200.0
S.T
PA.11 Internal
torque
command
% -250.0~250.0 10.0 T
PA.12 Internal
torque
limit % 0~300.0
250.0
P.S
PA.13 Max
speed
limit
r/min
0~5000.0
5000.0
P.S.T
PA.14
Max torque limit
%
0~300.0
300.0
P.S.T
PA.15 Jog
speed
r/min
0~1000.0
200.0
P.S.T
PA.16
Travel limit switch masking
-
0~1
0
P.S.T
PA.17 E-stop
masking - 0~1 0
P.S.T
PA.18 Factory
password - 0~65535 -
P.S.T