Operation Manual of INVT CHS100 AC Servo Drive 6 Detailed parameter description
84
Function
code
Name
Unit
Range
Default
Mode
Pc.18 Factory
reserved -
-
0
-
Pc.19
Matching resistor
selection
- 0~1 0 P.S.T
When adopt 485 communication, the matching resistors of equal resistance should be
fitted at the starting end and finishing end of the network.
0: the matching resistors are inactive;
1: the matching resistors are active.
Function
code
Name
Unit
Range
Default
Mode
Pc.20
Local drive
communication
address
- 0~31 1 P.S.T
This parameter is used to set the communication address of the local drive for RS485
serial communication.
Function
code
Name
Unit
Range
Default
Mode
*Pc.21 Communication
mode
-
0~1
0
P.S.T
This parameter is used to select the communication mode. The communication modes
are:
0: RS232;
1: RS485.
Function
code
Name
Unit
Range
Default
Mode
Pc.22
Communication baud
rate selection
- 0~4 0
P.S.T
This parameter is used to select the communication baud rate. Available baudrate are
as follow:
0:9600bps;
1:19200bps;
2:38400bps;