Operation Manual of INVT CHS100 AC Servo Drive 4 Signal and wiring
17
4.2 Wiring of the main circuit (Connectors X1 and X2)
4.2.1 Overview
Fig. 4-2 Wiring diagram of the main circuit
Motor
Breaker
Noise fil
ter
Electro
m
agne
tic
co
nt
act
or
AC rea
ct
or
z
Check whether the phase number/voltage grade
of the AC power supply are consistent with those
identification on the nameplate of the drive.
z
Non-fuse breaker or leakage switch.
z
Be sure to fit a noise filter.
z
Do not use this electromagnetic contactor to
start/stop the servo drive.
z
Please fit an AC reactor.
z
Do not disconnect the short circuit wire between B2
and B3 unless an external regenerative braking
resistor is used.
z
When an external regenerative braking resistor is
used, disconnect the short circuit wire between B2
and B3, and connect it according to the dashed in
the figure.
z
Be sure to ground the servo drive with proper
techniques to avoid the accident of electrical
shock.
z
Please set a circuit which can activate the
electromagnetic brake not only through the servo
drive but also through the external emergency stop
device. Please refer to section 4.6.
z
The electromagnetic brake has no polarity.
z
The electromagnetic brake uses 24V power supply
which should be provided by the user. Do not share
it
ith th
t l
i
l
l
The distance between the servo motor and the servo drive should not exceed 20m. Keep a
distance of at least 30cm between the encoder wire, motor cable and power cable.
Green/yellow
E-stop
Surge absorber
Fuse
Correctly connect to output U, V, and W of the drive
according to the phase sequence of the motor cable
of the servo motor. Wrong phase sequence will
cause drive fault.