Operation Manual of INVT CHS100 AC Servo Drive 5 Running and operation
57
Identifier
Name
Unit
Accuracy
Instantaneous value of U phase output current
when a fault occurs
A 0.01
Instantaneous value of phase V output current
when a fault occurs
A 0.01
Bus voltage when a fault occurs
V
0.1
5.2.3 Parameter setting
When “Basic parameter setting” is selected by pressing
, the panel displays
“PA.xx” (xx represent identifiers of different parameters). At this time, you can press
or
to select the identifier of the parameter to be set. After the selection,
press SET key, the panel will display the value of corresponding parameter with the
lowest digit flashing. You can change the value of the flashing digit by pressing
or
and move the flashing to modify the values of other digits by pressing
. After
finishing the modification, press
to execute the modified value, then the flashing
stops at the same time. You can press
again to modify the value of other
parameters. Press
to return.
The parameter selection flow chart is shown in the figure below:
Fig. 5-8 Flow chart of parameter selection
Please refer to chapter 5.2.1 for the operation flow after the related parameters are
selected.
The setting methods of the gain parameters and expansion parameters are the same
as the basic parameters.
5.2.4 Auxiliary functions
When auxiliary function mode is selected by pressing
, the panel will display the
identifier for auxiliary function. At this time, you can press
or
to select the
auxiliary function to be completed. The servo drive has the following auxiliary functions:
Or