Operation Manual of INVT CHS100 AC Servo Drive 4 Signal and wiring
24
current) of the servo drive or 12V – 24V power supply provided by the user.
4.5.3 Wiring of the pulse input circuit
Fig. 4-10 Wiring diagram of the pulse input circuit
Connection method 1, the maximum frequency of input pulse is 500kHz;
with the best anti-noise capability, this signal transmit method is
recommended as the preferred.
Connection
method 1
Connection
method 2
Connection
method 3
Shielded
wire
Shielded
wire
Shielded
wire
Twisted
pair
Twisted
pair
Twisted
pair