98
Intel RAID Controller SRCU32 User’s Guide
Repair Array Drives
This function allows the online repair of array drives which show failed drives. After selecting this
menu option, StorCon displays a summary of all installed array drives and the number of array
drives which are in critical states (Figure 32). In the example in Figure 33 there is one array drive
in the Fail state. For example, the array drive is still operating but no longer redundant.
Figure 32. Array Drive Summary
After pressing any key, StorCon displays a list of array drives which are candidates for online
automatic repair.
✏
NOTE
Array drives that are in the
Error
state are very critical and have lost two or even more drives.
These array drives cannot be repaired with the
Repair Array Drives
function. In such critical cases
data integrity can no longer be maintained.
After selecting the array drive, StorCon displays the drive that failed. In the example in Figure 33 it
is the hard drive which forms logical drive 5.
Figure 33. Failed Hard Drive
After confirmation, the failed drive must be removed from the system and the new one configured
on the same ID and installed in the system. See Figure 34 and Figure 35.
Figure 34. Select Drive to Repair
Содержание SRCU32 - RAID Controller
Страница 1: ...Intel RAID Controller SRCU32 User s Guide Order Number A77949 004 ...
Страница 35: ...Getting Started 35 Figure 9 Operational State Diagram for RAID 4 5 ...
Страница 46: ......
Страница 62: ...62 Intel RAID Controller SRCU32 User s Guide ...
Страница 76: ...76 Intel RAID Controller SRCU32 User s Guide ...
Страница 109: ...Storage Console 109 Figure 49 Block Diagram of a SAF TE Subsystem ...
Страница 122: ......
Страница 164: ...164 Intel RAID Controller SRCU32 User s Guide Figure 106 StorCon Help ...
Страница 167: ...Storage Console Plus 167 Figure 109 RAID Configuration Service Add Remove Users ...
Страница 170: ...170 Intel RAID Controller SRCU32 User s Guide ...