Introduction and General Information
19
Level 4
On level 4, the firmware forms the host drives. Only these drives can be accessed by the host
operating system of the computer. The firmware automatically transforms each newly installed
logical drive and array drive into a host drive. This host drive is then assigned a host drive number
which is identical to its logical drive or array drive number.
The firmware is capable of running several kinds of host drives at the same time. For example, in
Windows
†
2000, drive C is a RAID 5 type host drive (consisting of five SCSI hard drives), drive D
is a single hard drive. On this level the user may split an existing array drive into several host
drives.
After a capacity expansion of a given array drive the added capacity appears as a new host drive on
this level. It can be either used as a separate host drive, or merged with the first host drive of the
array drive. Within StorCon, each level of hierarchy has its own menu:
Level 1 - Configure Physical Devices
Level 2 - Configure Logical Drives
Level 3 - Configure Array Drives
Level 4 - Configure Host Drives
Generally, each installation procedure passes through these four menus, starting with level 1.
Installation includes the initializing the physical drives, configuring the logical drives, configuring
the array drives (for example, RAID 0, 1, 4, 5, and 10) and configuring the host drives.
Transparency of Host Drives
The structure of the host drives installed with StorCon (see Chapter 7, Storage Console) is not
known to the operating system. For example, the operating system does not recognize that a given
host drive consists of a number of hard drives forming a disk array.
To the operating system this host drive simply appears as one single hard drive with the capacity of
the disk array. This complete transparency represents the easiest way to operate disk arrays under
the operating system. Neither operating system nor the PCI computer need to be involved in the
administration of these complex disk array configurations.
Содержание SRCU32 - RAID Controller
Страница 1: ...Intel RAID Controller SRCU32 User s Guide Order Number A77949 004 ...
Страница 35: ...Getting Started 35 Figure 9 Operational State Diagram for RAID 4 5 ...
Страница 46: ......
Страница 62: ...62 Intel RAID Controller SRCU32 User s Guide ...
Страница 76: ...76 Intel RAID Controller SRCU32 User s Guide ...
Страница 109: ...Storage Console 109 Figure 49 Block Diagram of a SAF TE Subsystem ...
Страница 122: ......
Страница 164: ...164 Intel RAID Controller SRCU32 User s Guide Figure 106 StorCon Help ...
Страница 167: ...Storage Console Plus 167 Figure 109 RAID Configuration Service Add Remove Users ...
Страница 170: ...170 Intel RAID Controller SRCU32 User s Guide ...