Storage Console
103
The example in Figure 41 shows the slots of the enclosure which have been assigned with hard
drives. To fill an empty slot, press and select the desired hard drive. See Figure 41.
Figure 41. Enclosure Slots
SAF-TE and SES are recommended for auto hot pluggable subsystems. Only with these systems
can a secure auto hot plug be guaranteed. For non-intelligent subsystems we recommend only the
best quality components (disk shuttles, cables, terminators, etc.).
Advanced Settings
Within Advanced Settings there are three settings which control the configuration and address
behavior of the Intel RAID Controller SRCU32’s BIOS and DPMEM. See Figure 42 and Table 16
for setting details.
Figure 42. Advanced Settings Dialog
Table 16. Advanced Settings
Parameter Alternatives
Description
Off
The BIOS is not shrinked after the post phase.
On
The BIOS is always shrinked after the post phase.
Shrink BIOS after
POST
Auto
The Intel RAID Controller SRCU32 decides on the BIOS shrink.
Auto
The BIOS address space is automatically allocated.
BIOS RAM
allocation method
Older
The BIOS address space is allocated according to an older PCI
specification.
Move below
1MB
The DPMEM address space is allocated below 1 MB.
DMEM mapping
Do not move
The DPMEM address is always above 1 MB.
Содержание SRCU32 - RAID Controller
Страница 1: ...Intel RAID Controller SRCU32 User s Guide Order Number A77949 004 ...
Страница 35: ...Getting Started 35 Figure 9 Operational State Diagram for RAID 4 5 ...
Страница 46: ......
Страница 62: ...62 Intel RAID Controller SRCU32 User s Guide ...
Страница 76: ...76 Intel RAID Controller SRCU32 User s Guide ...
Страница 109: ...Storage Console 109 Figure 49 Block Diagram of a SAF TE Subsystem ...
Страница 122: ......
Страница 164: ...164 Intel RAID Controller SRCU32 User s Guide Figure 106 StorCon Help ...
Страница 167: ...Storage Console Plus 167 Figure 109 RAID Configuration Service Add Remove Users ...
Страница 170: ...170 Intel RAID Controller SRCU32 User s Guide ...