34
Intel RAID Controller SRCU32 User’s Guide
Operational States of an Intel RAID Controller SRCU32
Firmware Disk Array
Operational States for RAID 4/5
An array drive under the Intel RAID Controller SRCU32 firmware operating system can assume
seven different operational states: Idle, Ready, Fail, Build, Rebuild, Expand, and Error. Table 9
describes the operational states for RAID 4/5 while Figure 9 is the operational state diagram for
RAID 4/5 Table 10 describes additional operational states.
Table 9.
Operational States for RAID 4/5
State
Description
Idle State
This state is characterized by the fact that the redundant information of the disk
array has never been entirely created. The disk array is in this state after its first
configuration and until you quit Storage Console (StorCon). Should an error occur
while the array is in the build state, the array returns to the Idle state (exception: if
during build state the dedicated drive of RAID 4 fails, the state changes to fail.
Build State
After the disk array has been configured for the first time, it assumes the build state
as soon as you quit StorCon. While the array is in the Build state, redundancy
information is calculated and stored to the hard drives of the array.
Ready State
The disk array is fully operational when in the Ready state. All redundant
information is present, that is, a hard drive can fail without impairing the
functionality of the disk array. This is the normal state of a disk array. The state
ready/expand indicates that the RAID level and/or capacity are currently
migrated/expanded.
Fail State
The disk array changes to the fail state whenever a Logical Drive fails.
Redundancy information is still present, thus allowing the remaining hard drives to
continue working. This state should be eliminated as soon as possible by replacing
the defective hard drive. If a so-called Hot Fix drive has previously been assigned
to a disk array with StorCon, the controller will automatically replace the defective
drive and start the reconstruction of the data and the redundant information.
Therefore, under these circumstances the fail state is only temporary and will be
eliminated by the controller itself.
Rebuild State
The disk array will assume this state after the automatic activation of a Hot Fix
drive or after a manual replacement is carried out with StorCon. The data and the
redundant information are reconstructed and stored to the new drive.
Expand State
If the capacity or RAID level of an existing disk array is changed, the disk array
changes its state into expand. As soon as the expansion or migration is
completed, the state changes back to ready.
Содержание SRCU32 - RAID Controller
Страница 1: ...Intel RAID Controller SRCU32 User s Guide Order Number A77949 004 ...
Страница 35: ...Getting Started 35 Figure 9 Operational State Diagram for RAID 4 5 ...
Страница 46: ......
Страница 62: ...62 Intel RAID Controller SRCU32 User s Guide ...
Страница 76: ...76 Intel RAID Controller SRCU32 User s Guide ...
Страница 109: ...Storage Console 109 Figure 49 Block Diagram of a SAF TE Subsystem ...
Страница 122: ......
Страница 164: ...164 Intel RAID Controller SRCU32 User s Guide Figure 106 StorCon Help ...
Страница 167: ...Storage Console Plus 167 Figure 109 RAID Configuration Service Add Remove Users ...
Страница 170: ...170 Intel RAID Controller SRCU32 User s Guide ...