Storage Console
93
Figure 26. Select Host Drive
Some of the states listed below may have the addition of /patch (for example build/patch,
ready/patch). This indicates that the original array drive went through a significant procedure, for
example, the parity information was recalculated anew. Or, the array drive has been patched from
the error state into the fail state. This may become helpful in a situation where two logical drives of
an array drive fail at the same time, but only one of the two logical drives is really defective and the
other was blocked out since it was connected with the same I/O channel as the defective one. The
array drive’s state is error and normally all data would be lost. Intel RAID Controller SRCU32
includes some functions that allow the patch of this array drive from the error state into the fail sate.
Before the actual patch, the defective drive has to be physically removed from the array drive.
Such a patch procedure should only be used after a consultation with a trained support person (a
printout of the Save Information file, is extremely helpful).
Pressing <F4> delivers level-by-level detailed information on a host drive and its components.
This may assist in getting an overview of a specific host drive. After pressing <F5>, the Intel
RAID Controller SRCU32 switches the LEDs (if available) of the hard drives belonging to that host
drive on and off.
Idle State:
The idle state is characterized by the fact that the redundant information of the disk array has never
been entirely created. The disk array is in this state after its first configuration and until you quit
StorCon. Should an error occur while the array is in the build state, the array returns to idle. The
exception is that if during build mode the dedicated drive of RAID 4 fails, the mode changes to fail.
Build State:
After the disk array has been configured for the first time, it assumes the build state as soon as you
quit StorCon. While the array is in the build state, redundancy information is calculated and stored
to the hard drives of the array.
Содержание SRCU32 - RAID Controller
Страница 1: ...Intel RAID Controller SRCU32 User s Guide Order Number A77949 004 ...
Страница 35: ...Getting Started 35 Figure 9 Operational State Diagram for RAID 4 5 ...
Страница 46: ......
Страница 62: ...62 Intel RAID Controller SRCU32 User s Guide ...
Страница 76: ...76 Intel RAID Controller SRCU32 User s Guide ...
Страница 109: ...Storage Console 109 Figure 49 Block Diagram of a SAF TE Subsystem ...
Страница 122: ......
Страница 164: ...164 Intel RAID Controller SRCU32 User s Guide Figure 106 StorCon Help ...
Страница 167: ...Storage Console Plus 167 Figure 109 RAID Configuration Service Add Remove Users ...