Storage Console
95
Figure 27. Choose Type
StorCon displays a security message pointing out that all existing data on the selected hard drives
will be destroyed. Confirm by pressing <Y> (Figure 28).
Figure 28. Create Host Drive Confirmation
After pressing <Y> the user may limit the capacity of each hard drive selected for the new host
drive (Figure 29). This can be helpful when procuring future spare hard drives. StorCon then
creates and configures the new host drive and adds it to the list. All SCSI parameters are adjusted
to optimum values.
Figure 29. Hard Drive Capacity
✏
NOTE
If the entire hard disk capacity is not used when configuring a RAID 1 host drive, you cannot use
the remaining capacity to expand the array drive in the future.