157
4. Disk Roaming from 4600U/T to 12600U rack-mount models:
4-1. Power down the 4600U/T system.
4-2. Remove all member drives belonging to a logical volume. Re-install them to the
drive trays of the 12600U series systems.
4-3. Install these member drives to the 12600U system.
4-4. If the 12600U system is online and running, move to the Storage > Volume page to
bring the volume online.
4-5. If the 12600U system is offline, power it on a
nd the volume is automatically brought
online later.
5. Faulty disk replacement Procedure:
5-1. If a disk drive fails in an online volume, replace it with a new disk drive. The system
will begin the online rebuild.
5-2. If a disk drive fails in an online volume, you can install the replacement drive in an
unused disk bay. You can then enter the volume management window and replace
the faulty drive with the new, replacement drive.
5-3. If multiple members of a volume have been removed, the system will automatically
bring the volume offline.
5-4. An offline volume, (meaning that when a system is powered down; or the members
of a volume moved to a different chassis), can have its member drives installed
in disorderly drive bay positions. The system will automatically detect the logical
volume information and the whereabouts of its members. The user can then bring
the volume online.
Содержание nastorage 12600 series
Страница 1: ...1 NAStorage 4600 12600 12620 Series Tower 1U 2U Rack mount User Manual Rev 1 1 ...
Страница 16: ...16 6 Use the bezel key to lock the drive tray Repeat the above process to install more disk drives Bezel Lock ...
Страница 24: ...24 3 Attach the inner rails to the sides of the chassis 4 Gradually slide the chassis into rack ...
Страница 50: ...50 4 Click to open the Trusted Root Certification Authorities tab Click the Import button ...
Страница 59: ...59 5 Save the compiled module to a position as shown below ...
Страница 158: ...158 ...