VoIP Debugging
329
Software Configuration Guide Release 2.10, Revision 1.00
SN2>
enable
RTT:
Minimum <10ms, Maximum <10ms, Average <10ms
33.6 Verify Circuit Switch Connectivity
The following commands makes possible to establish voice calls between two endpoints without
additional voice devices such as voice phones. Additionally the set up and shut down of voice calls
can be traced by the debug monitor and established calls can be displayed by the show command.
Procedure
Verify Circuit Switch Connectivity by set up and trace voice calls
Mode
Administrator execution
Command
Purpose
Step 1
node2(
if-
type
)[
if-name
]#routing dest-
interface callapp
The call from the H.323 or ISoIP
interface must be routed to the
interface 'callapp' to accept it with
SmartWare.
Step 2
node2(
if-
type
)[
if-name
]#exit
Step 3
node2(
ctx-cs)[switch]#no shutdown
Enable the configuration
Step 4
node2(
ctx-cs)[switch]#exit
Step 5
node2
(cfg)#exit
Step 6
node2
#debug call [
detail level
]
Enable call debug monitor on
SmartNode number 2.
Step 7
node1
#debug call [
detail level
]
Enable call debug monitor on
SmartNode number 1.
Step 8
node1
#call
callkey
dial
interface
Set up the call with the call ID
callkey
and over the interface
interface
on
SmartNode number 1.
Step 9
node2
#call
callkey
accept
Accept the call on SmartNode number
2. You will get the
callkey
from the
debug monitor.
Step 10
node2
#show call sessions [
detail level
]
Step 11
node1
#show call sessions [
detail level
]
Display the actual running call
application session(s). If there is one
displayed on both endpoints the
connection was established.
Step 12
node1
#call
callkey
drop
Tear down the call on both endpoints.
Example: Verify Circuit Sw itch Connectivity
The following example shows how to establish a voice connection between two endpoints. Note that
to perform this example you need a fully operative configuration on both endpoints. The following
configuration steps only illustrate how to set up and shut down a voice call.
SmartNode 2: Route calls from ISoIP interface
ISOIP_IF
to interface
callapp
and enable debug
monitor.
Содержание SmartWare Release 2.10
Страница 2: ...2 Legal Notice Software Configuration Guide Release 2 10 Revision 1 00...
Страница 15: ...Terms and Definitions 15 Software Configuration Guide Release 2 10 Revision 1 00...
Страница 218: ...218 PPP Configuration no shutdown Software Configuration Guide Release 2 10 Revision 1 00...
Страница 272: ...272 Tone Configuration Software Configuration Guide Release 2 10 Revision 1 00...